Browsing by Author "Bou-Saada, T. E."
Now showing items 1-13 of 13
-
Bou-Saada, T. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)This manual outlines the procedures to collect data, poll the datalogger, and process the data. The processed data is then used with a calibrated DOE-2 input file using statistical graphing routines for the U.S.D.O.E. ...
-
Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)This report contains engineering calculations for seven (7) air-side, heating, ventilating and air conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), ...
-
Bou-Saada, T. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1993)The Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features, including a photovoltaic system, solar hot water system, energy efficient lighting, ...
-
Bou-Saada, T. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)The U.S.D.O.E. Forrestal Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features such as efficient lighting, a photovoltaic system, an energy ...
-
Heneghan, T.; Haberl, J. S.; Saman, N.; Bou-Saada, T. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)Building energy simulation programs have undergone an increase in use for evaluating energy consumption and energy conservation retrofits in buildings. Utilization of computer simulation programs for large facilities ...
-
Bou-Saada, T. E.; Munger, B. K.; Saman, N. F.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), 1995-12)The intent of this project was to model each of the large buildings at the Karnes County 2,250 bed and Cuero 1,000 bed prison sites with the DOE-2 building energy simulation program and to deliver a working model to the ...
-
Bou-Saada, T. E.; Culp, C. (Texas A&M University (http://www.tamu.edu); Energy Systems Laboratory (http://esl.tamu.edu), 2005)
-
Bou-Saada, T. E.; Culp, C. (Texas A&M University (http://www.tamu.edu); Energy Systems Laboratory (http://esl.tamu.edu), 2006)
-
Culp, C.; Bou-Saada, T. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2007-12)The Texas Mental Health and Mental Retardation agency, now part of the Texas Health and Human Services Commission, was challenged to deal with regularly deteriorating infrastructure at twentythree large campuses located ...
-
Haberl, J. S.; Bou-Saada, T. E.; Vajda, E. J.; Shincovich, M.; D'Angelo III, L.; Harris, L. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)In September of 1993 a 36,832 fixture lighting retrofit was completed at the United States Department of Energy Forrestal complex in Washington, D.C. This retrofit represents DOE's largest project to date that utilizes a ...
-
Haberl, J. S.; Bou-Saada, T. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1995)This report provides an overview of the lighting retrofit and the resultant electricity and thermal savings. It presents results from the whole-building monitoring effort that show that the measured gross electricity savings ...
-
Soebarto, V.; Reddy, A.; Bou-Saada, T. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)This paper describes a project where selected energy conservation measures in two Habitat for Humanity houses in Houston, Texas were measured using side-by- side measurements of identical houses and calibrated simulation. ...
-
Saman, N.; Heneghan, T.; Bou-Saada, T. E. (Texas A&M University (http://www.tamu.edu); Energy Systems Laboratory (http://esl.tamu.edu), 1996)This study investigates the feasibility of using direct and indirect evaporative cooling systems for correctional facilities in two different Texas climatic regions with the DOE-2.1E hourly energy simulation program. ...